• Universal Parts 12V 4.5AH Battery – SLA12-4.5

    Rated 0 out of 5
    00

    • 12 Volt, 4.5 AH
    • Faston: 0.187 inch
    • Length: 3.54 inches (90mm)
    • Width: 2.72 inches (69mm)
    • Height: 4.00 inches (102mm)

  • Shorai Lithium Battery 12V 9Ah

    Rated 0 out of 5
    00
    • Length: 113mm (4.45 inches)
    • Width: 58mm (2.28 inches)
    • Height: 89mm (3.50 inches)
    • “A” Polarity
    • CCA (cold cranking amps): 135
    • No More Dead Batteries – Holds Charge For 1 Year Without Maintenance
    • Ultra Light – One Fifth The Weight of Lead Acid Batteries On Average
    • Zero Sulfation For Longer Service Life
    • Drop-In Replacement For Your OEM Battery
    • Military Spec Carbon Composite Case
    • Faster Cranking For Better Starts
    • Super Fast Recharge Rate
    • SAFE – No Explosive Gasses During Charge, No Lead, No Acid
    • Environmentally Friendly – Just Discharge & Dispose
    • Japanese Engineering
    • 3 Year Warranty!
    • Please Note: Shorai Batteries require a charging system output of 13.1 Volts or higher at idle, and must not exceed 15.2 volts at maximum output.
  • Shorai Lithium Battery 12V 9Ah

    Rated 0 out of 5
    00
    • Length: 113mm (4.45 inches)
    • Width: 58mm (2.28 inches)
    • Height: 89mm (3.50 inches)
    • “L” Polarity
    • CCA (cold cranking amps): 135
    • No More Dead Batteries – Holds Charge For 1 Year Without Maintenance
    • Ultra Light – One Fifth The Weight of Lead Acid Batteries On Average
    • Zero Sulfation For Longer Service Life
    • Drop-In Replacement For Your OEM Battery
    • Military Spec Carbon Composite Case
    • Faster Cranking For Better Starts
    • Super Fast Recharge Rate
    • SAFE – No Explosive Gasses During Charge, No Lead, No Acid
    • Environmentally Friendly – Just Discharge & Dispose
    • Japanese Engineering
    • 3 Year Warranty!
    • Please Note: Shorai Batteries require a charging system output of 13.1 Volts or higher at idle, and must not exceed 15.2 volts at maximum output.
  • Shorai Lithium Battery 12V 7Ah

    Rated 0 out of 5
    00
    • Length: 113mm (4.45 inches)
    • Width: 58mm (2.28 inches)
    • Height: 89mm (3.50 inches)
    • “L” Polarity
    • CCA (cold cranking amps): 102
    • No More Dead Batteries – Holds Charge For 1 Year Without Maintenance
    • Ultra Light – One Fifth The Weight of Lead Acid Batteries On Average
    • Zero Sulfation For Longer Service Life
    • Drop-In Replacement For Your OEM Battery
    • Military Spec Carbon Composite Case
    • Faster Cranking For Better Starts
    • Super Fast Recharge Rate
    • SAFE – No Explosive Gasses During Charge, No Lead, No Acid
    • Environmentally Friendly – Just Discharge & Dispose
    • Japanese Engineering
    • 3 Year Warranty!
    • Please Note: Shorai Batteries require a charging system output of 13.1 Volts or higher at idle, and must not exceed 15.2 volts at maximum output.
  • Universal Parts 12V 6AH Battery YTX7A-BS – Factory Activated

    Rated 0 out of 5
    00
    • Length: 5.94 inches (151mm)
    • Width: 3.40 inches (87mm)
    • Height: 3.70 inches (94mm)
    • Factory Activated – Ready to Install!
    • CCA (cold cranking amps): 90
    • Uses M6x12mm Battery Terminal Bolt Set
  • Universal Parts 12V 4.5AH Battery YTX5L-BS – Factory Activated

    Rated 0 out of 5
    00
    • Length: 4.43 inches (113mm)
    • Width: 2.72 inches (69mm)
    • Height: 4.14 inches (105mm)
    • Factory Activated – Ready to Install!
    • CCA (cold cranking amps): 70
    • Uses M5x8mm Battery Terminal Bolt Set
  • Universal Parts 12V 3AH Battery YTX4L-BS – Factory Activated

    Rated 0 out of 5
    00
    • Length: 4.45 inches (113mm)
    • Width: 2.72 inches (69mm)
    • Height: 3.39 inches (86mm)
    • Factory Activated – Ready to Install!
    • CCA (cold cranking amps): 50
  • Universal Parts 12V 7.6AH Battery SLA12-7.2

    Rated 0 out of 5
    00
    • 12 Volt 7.6 AH
    • Length: 5.94 inches (151mm)
    • Width:2.56 inches (65mm)
    • Height: 3.70 inches (94mm)
    • Faston: 0.250 inch (T2 Type)
  • Universal Parts Battery Terminal Connector

    Rated 0 out of 5
    00

    • Sold individually
    • Includes clear protective cover
    • Crimping tool required for attaching to wire

  • Universal Parts Battery Adaptor for Razor E200/300

    Rated 0 out of 5
    00

    • Compatible with belt driven E200/E200S and green E300/E300S scooters

  • Universal Parts 12V 18AH Battery – SLA12-18

    Rated 0 out of 5
    00

    • 12 Volt 18 Ah

    • Length: 7.17 inches (182mm)

    • Width: 3.03 inches (77mm)

    • Height: 6.57 inches (167mm)

  • Universal Parts 12V 6AH Battery YTX7A-BS

    Rated 0 out of 5
    00
    • Length: 5.90 inches (150mm)
    • Width: 3.40 inches (86mm)
    • Height: 3.70 inches (94mm)
    • Includes Acid Pack
    • CCA (cold cranking amps): 90
    • Uses M6x12mm Battery Terminal Bolt Set


    Set-Up Instructions

    All AGM battery electrolyte containers are not the same. Each contains the proper amount of electrolyte for its specific battery. Before filling, read the electrolyte handling instructions and precautions on the label. Do not smoke when activating a battery or handling battery acid. Always wear plastic gloves and protective eye wear and be sure to read the Battery Safety section in this manual. The following seven steps should be used to activate an AGM battery:

    1. The battery must be out of the vehicle and placed on a level surface.

    2. Remove electrolyte container from the plastic storage bag. Remove the strip of caps. Put the strip aside as you will use it later to seal the battery cells. For battery filling use only the dedicated acid container that comes with the battery as it contains the proper amount of electrolyte for that specific battery. This is important to service life and battery performance. Do not pierce, or otherwise open the foil seals on the electrolyte container. Do not attempt to separate the individual electrolyte containers.

    3. Place the electrolyte container with the foil seals facing down into the cell filler ports on the battery. Hold the container level and push down to break the foil seals. Electrolyte will start to flow into the battery and air bubbles will be seen inside the container. Do not tilt the electrolyte container.

    4. Check the electrolyte flow. Keep the container in place until it empties completely. If no air bubbles are coming up from the filler ports, or if container cells haven’t emptied completely after 20 minutes, tap the container and/or battery case a few times to cause the electrolyte to flow into the battery. Do not remove the acid container from the battery until it is completely empty. The battery requires all of the electrolyte from the container for proper operation. Bubbles will appear as the electrolyte container fills the battery indicating the flow of battery acid. Tap the container periodically to keep the electrolyte flowing until the container is completely empty. Never puncture the top of the acid container to speed up the filling process.

    5. Remove the empty electrolyte container from the battery. Fully insert the strip of sealing caps (previously removed from the electrolyte container) into the battery filling ports. Make sure the strip of caps is fully inserted and flush with the top of the battery. Insert the caps by hand, do not use a hammer or excessive force. Never remove the strip of caps or add water or electrolyte to the battery during its service life.

    6. For batteries with ratings of less than 18 AH, let the battery stand for 20 to 60 minutes. For batteries with higher AH ratings allow the battery to stand for 1 to 2 hours. Universal Parts AGM batteries have the amp hour (AH) printed on the front of the battery case. The stand, or rest period, allows the electrolyte to permeate into the plates for optimum performance.

    7. Newly activated AGM batteries require an initial charge. After adding electrolyte, a new battery is approximately 75-80% charged. After the “stand” period (step 6), charge the battery to bring it to a full state-of charge. The battery charger used for initial charging should be able to charge at 12.8+-volts for an AGM battery.

  • Universal Parts 12V 4AH Battery YTX5L-BS

    Rated 0 out of 5
    00
    • Length: 4.40 inches (112mm)
    • Width: 2.70 inches (69mm)
    • Height: 4.13 inches (105mm)
    • Includes Acid Pack
    • CCA (cold cranking amps): 70
    • Uses M5x8mm Battery Terminal Bolt Set


    Set-Up Instructions

    All AGM battery electrolyte containers are not the same. Each contains the proper amount of electrolyte for its specific battery. Before filling, read the electrolyte handling instructions and precautions on the label. Do not smoke when activating a battery or handling battery acid. Always wear plastic gloves and protective eye wear and be sure to read the Battery Safety section in this manual. The following seven steps should be used to activate an AGM battery:

    1. The battery must be out of the vehicle and placed on a level surface.

    2. Remove electrolyte container from the plastic storage bag. Remove the strip of caps. Put the strip aside as you will use it later to seal the battery cells. For battery filling use only the dedicated acid container that comes with the battery as it contains the proper amount of electrolyte for that specific battery. This is important to service life and battery performance. Do not pierce, or otherwise open the foil seals on the electrolyte container. Do not attempt to separate the individual electrolyte containers.

    3. Place the electrolyte container with the foil seals facing down into the cell filler ports on the battery. Hold the container level and push down to break the foil seals. Electrolyte will start to flow into the battery and air bubbles will be seen inside the container. Do not tilt the electrolyte container.

    4. Check the electrolyte flow. Keep the container in place until it empties completely. If no air bubbles are coming up from the filler ports, or if container cells haven’t emptied completely after 20 minutes, tap the container and/or battery case a few times to cause the electrolyte to flow into the battery. Do not remove the acid container from the battery until it is completely empty. The battery requires all of the electrolyte from the container for proper operation. Bubbles will appear as the electrolyte container fills the battery indicating the flow of battery acid. Tap the container periodically to keep the electrolyte flowing until the container is completely empty. Never puncture the top of the acid container to speed up the filling process.

    5. Remove the empty electrolyte container from the battery. Fully insert the strip of sealing caps (previously removed from the electrolyte container) into the battery filling ports. Make sure the strip of caps is fully inserted and flush with the top of the battery. Insert the caps by hand, do not use a hammer or excessive force. Never remove the strip of caps or add water or electrolyte to the battery during its service life.

    6. For batteries with ratings of less than 18 AH, let the battery stand for 20 to 60 minutes. For batteries with higher AH ratings allow the battery to stand for 1 to 2 hours. Universal Parts AGM batteries have the amp hour (AH) printed on the front of the battery case. The stand, or rest period, allows the electrolyte to permeate into the plates for optimum performance.

    7. Newly activated AGM batteries require an initial charge. After adding electrolyte, a new battery is approximately 75-80% charged. After the “stand” period (step 6), charge the battery to bring it to a full state-of charge. The battery charger used for initial charging should be able to charge at 12.8+-volts for an AGM battery.

  • Universal Parts 12V 3AH Battery YTX4L-BS

    Rated 0 out of 5
    00
    • Length: 4.40 inches (112mm)
    • Width: 2.74 inches (70mm)
    • Height: 3.39 inches (86mm)
    • Includes Acid Pack
    • CCA (cold cranking amps): 50
    • Uses M5x8mm Battery Terminal Bolt Set


    Set-Up Instructions

    All AGM battery electrolyte containers are not the same. Each contains the proper amount of electrolyte for its specific battery. Before filling, read the electrolyte handling instructions and precautions on the label. Do not smoke when activating a battery or handling battery acid. Always wear plastic gloves and protective eye wear and be sure to read the Battery Safety section in this manual. The following seven steps should be used to activate an AGM battery:

    1. The battery must be out of the vehicle and placed on a level surface.

    2. Remove electrolyte container from the plastic storage bag. Remove the strip of caps. Put the strip aside as you will use it later to seal the battery cells. For battery filling use only the dedicated acid container that comes with the battery as it contains the proper amount of electrolyte for that specific battery. This is important to service life and battery performance. Do not pierce, or otherwise open the foil seals on the electrolyte container. Do not attempt to separate the individual electrolyte containers.

    3. Place the electrolyte container with the foil seals facing down into the cell filler ports on the battery. Hold the container level and push down to break the foil seals. Electrolyte will start to flow into the battery and air bubbles will be seen inside the container. Do not tilt the electrolyte container.

    4. Check the electrolyte flow. Keep the container in place until it empties completely. If no air bubbles are coming up from the filler ports, or if container cells haven’t emptied completely after 20 minutes, tap the container and/or battery case a few times to cause the electrolyte to flow into the battery. Do not remove the acid container from the battery until it is completely empty. The battery requires all of the electrolyte from the container for proper operation. Bubbles will appear as the electrolyte container fills the battery indicating the flow of battery acid. Tap the container periodically to keep the electrolyte flowing until the container is completely empty. Never puncture the top of the acid container to speed up the filling process.

    5. Remove the empty electrolyte container from the battery. Fully insert the strip of sealing caps (previously removed from the electrolyte container) into the battery filling ports. Make sure the strip of caps is fully inserted and flush with the top of the battery. Insert the caps by hand, do not use a hammer or excessive force. Never remove the strip of caps or add water or electrolyte to the battery during its service life.

    6. For batteries with ratings of less than 18 AH, let the battery stand for 20 to 60 minutes. For batteries with higher AH ratings allow the battery to stand for 1 to 2 hours. Universal Parts AGM batteries have the amp hour (AH) printed on the front of the battery case. The stand, or rest period, allows the electrolyte to permeate into the plates for optimum performance.

    7. Newly activated AGM batteries require an initial charge. After adding electrolyte, a new battery is approximately 75-80% charged. After the “stand” period (step 6), charge the battery to bring it to a full state-of charge. The battery charger used for initial charging should be able to charge at 12.8+-volts for an AGM battery.

  • Universal Parts 48v Charger Adapter

    Rated 0 out of 5
    00

    • Overall Length: 12.5 inches
    • Plug Style: 3 Spade Male / 3 Spade Female

Main Menu